General Data:
Dimension(mm):
Parameters(25°C) Model
SCD20-10mA
SCD20-50mA
SCD20-100mA
SCD20-500mA
Nominal Rms Current (Ipn)
0 ~±10mA DC
0~±50mA DC
0~±100mA DC
0~±500mA DC
Measuring Range (Ip)
0 ~±12mA DC
0~±50mA DC
0~±100mA DC
0~±500mA DC
Load resistance Rmax
≥10kΩ
Output Voltage
3V±2V
Working voltage
DC +12V (±5%)
Accuracy @ Ta=25°C
±1.5%
Linearity @ Ta=25°C
±1%
Offset Voltage
3V ±50mV
Thermal drift of Vo
< ±3mV/°C
Resolution
±1%
Immunity (to external interference)
< ± 5mV When H=50A DC/m
Weight
SCD20 420g
Withstand voltage
3kVrms/50Hz/min
Response time
<400mS
Current consumption
<18mA
Operating temperature
-40~+80 °C
Storage temperature
-40~+85 °C
Notes:
1. Size error: ±1mm;
2. Primary aperture: φ60mm;
3. Fastening hole: φ6mm*2;
4. Output terminal: 2EDGVC-5.08-4P;
5. The IP indication direction is the positive direction of the current, OFS is the zero adjustment, and GIN is the output regulation;
6. Incorrect wiring may cause damage to the sensor;
7. The zero voltage of the sensor can be adjusted appropriately according to the needs of users;
Instructions
1.DC leakage current sensor adaptnon-contact measurement, it is develop on the basis of the principle of zeromagnetic flux modulation and magnetic modulation, it can measure small DCcurrent MA level’s isolation in perforation measurement.
2.Zero position output of the sensor outputcan be adjusted according to user needs.
3.We can customize different current andvoltage output according to user's requirements.
Caution: This product is precisionmeasuring device, please handle with care!