General Data:
Dimension(mm):
Parameters(25°C) Model
SCD3-AC -10mA
SCD3-AC -20mA
SCD3-AC -50MA
SCD3-AC -100mA
Nominal Rms Current (Ipn)
±10mA
±20mA
±50mA
±100mA
Measuring Range (Ip)
2* Ipn
Load resistance Rmax
≥10kΩ
Output Voltage
±5V(DC) 5V(AC)
Working voltage
±12V~±15V(±5%)
Accuracy @ Ta=25°C
±1% FS
Linearity @ Ta=25°C
±1% FS
Input Offset Voltage
SCD3-AC<±150mV
Thermal drift of Vo
< ±1mV/°C
Resolution
10uA
immunity (to external interference)
< ± 5mV When H=50A DC/m
Weight:
SCD3-AC 450g
Withstand voltage
3kVrms/50Hz/min
Current consumption
<20mA
Operating temperature
-10~+75 °C
Storage temperature
-25~+80 °C
Instructions
1.SCD-AC Series sensor is AC/DC leakage current sensor adapt non-contact
measurement, it can measure small AC, DC current MA level’s isolation in
perforation measurement. M2 measure AC output, M1 measure DC output. 2.Zero
position output of the sensor output can be adjusted according to user
needs.
3.AC-GIN adjust the AC output value, DC-OFS adjust the zero DC.
Caution: This product is precision measuring device, please handle with care!