Technical Data:
Parameters(25°C) Model | SCB6-50A | SCB6-100A |
Nominal Rms Current (Ipn) | ±50AT | ±100AT |
Measuring Range (Ip) | 75AT | 150AT |
Road Resistance Rmax | 50~100Ω | 20~80Ω |
Output current | ±50mA | |
Turns Ratio | 0.736111111 | 1.430555556 |
Measuring Resistance | 80Ω | 120KΩ |
Working voltage | DC ±12V or ±15V (±5%) | |
Accuracy @ Ta=25°C | ±0.5% FS | |
Linearity @ Ta=25°C | ±0.1% FS | |
Offset Voltage | < ±0.2mA | < ±0.1mA |
Offset temperature characteristics | < ±0.2%/°C | |
Thermal drift of Vo | Typical values ± 0.1mA, maximum ±0.5mA | Typical values ± 0.05mA, maximum ±0.25mA |
Di/Dt following accuracy | >100A/us | |
Bandwidth | DC ~100kHz | |
Response time | < 1uS | |
Hysteresis offset | < 0.5mA (if=F.S. 0<------>Nominal RMS Current) | |
Withstand voltage | 3kVrms/50Hz/min | |
Current consumption | 10mA + output current | |
Operating temperature | -20~+80 °C | |
Storage temperature | -40~+85 °C |
Notes:
1. Size error: ±0.5mm;
2. Primary aperture: □15*7.2mm;
3. Lead output: □ 0.7*0.6mm*3;
4. The IP indication direction is the positive direction of the current;
5. Incorrect wiring may cause damage to the sensor.
Instructions
1. SCB6 Series is close-loop currentsensor. There is galvanic isolation between primary and secondary circuit
provides accurate electronic measurement of DC, AC or pulse currents.
2. Square perforation, mainly measure cooper conductor current.
3. Current output.
4. Advantages: Wide bandwidth, excellent accuracy, good linearity and fastresponse.
Caution: Incorrect wiring may damage the sensor