Technical Data:
Parameters(25℃)/Model | SCY6D- | |||
100A | 200A | 300A | 500A | |
Nominal Rms Current (Ipn) | ±100AT | ±200AT | ±300AT | ±500AT |
Measuring Range (Ip) | 400AT | 600AT | 800AT | 1000AT |
Load resistance Rmax | ≥10KΩ | |||
Output Voltage | 2.5V±2V or 4-20mA | |||
Working voltage | DC +12V (±5%) | |||
Accuracy @ Ta=25°C | ±1% | |||
Linearity @ Ta=25°C | ±1% | |||
Withstand voltage | 2.5 kVrms/50Hz/1min | |||
Zero Voltage | 30V ±% | |||
Offset temperature characteristics | < ±0.08%/°C | < ±0.05%/°C | ||
Thermal drift of Vo | <±2mV/°C | <±1mV/°C | ||
Hysteresis offset | <30mV | <20mV (If=F.S. 0<--->Nominal input current) | ||
Response time | < 5uS | |||
Current consumption | <25mA | |||
Operating temperature | -20~+80 °C | |||
Storage temperature | -40~+85 °C | |||
Hole inside (mm) | diameter 21 |
Dimension(mm):
Hole diameter 20mm
Instructions:
1. SCY6D Series 's up and down can open and close without removing the busbar line, easy to install.
2. Based on open-loop principle,it can measure DC, AC and Pulse current.
3. Round perforation,diameter 20mm, mainly measure wire conductor current.
4. Features: High accuracy, low power consumption, high liability and strong overload capacity.
5. Can be customized according to the requirements of the product
Caution: Incorrect wiring may damage the sensor.
Note: Can customized 30A, 50A as the primary input current.