General Data:
Parameters(25°C) Model | SVL 2 | |
Current output | ||
Rated input voltage | DC: 0~300V, 0~1000V | |
Rated output | DC: 4~20mA | |
Accuracy @ Ta=25°C | ±1% | |
Working voltage | DC ±12V (±5%) | |
Road Resistance Rmax | 250Ω | |
Overload Voltage | 1.2Uin | |
Offset Current | < ±0.125mA | |
Linearity @ Ta=25°C | ±0.5% | |
Response time | 300mS | |
Thermal drift of Offset Vo | < ±0.02%/°C | |
Withstand voltage | 3kVrms/50Hz/min | |
Current consumption | < 110mA + output current | |
Operating temperature | -25 ℃ ~ +85℃ | |
Storage temperature | -40 ℃ ~ +90℃ |
Drawing & Wiring (mm):
Notes:
1. Size error: ±1mm;
2. If the rated voltage ≥ 500V, the input/output is a single channel detection.
3. The product installation and use environment should be free of conductive dust and corrosion.
4. When wiring, please pay attention to the exposed conductive part of the terminal block, and the input, output and power supply must be connected correctly.
Do not make mistakes or reverse connections, incorrect wiring may cause damage to the sensor.
5. Severe vibration or high temperature may also cause damage to the product, please pay attention to the occasion of use.
Instructions
1.Single DC voltage isolation conversion,convert the high DC voltage signal 0-1000V into standard output or 4-20mAcurrent signal, easy measurement.
2.Directly connect with all types of A / D converter, and also can directlyconnect to the digital panel meter or other indicating instruments.
3.Rail mounting, simple and convenient.